Clever

Clever Box

Componenti 1
  • 230Vac 50Hz single-phase power supply protected by fuse and overvoltage circuit breaker
  • Maximum absorbed power 5W
  • Analog measurement of two active powers by means of 2 analog inputs to measure the current by CT and 1 input, that is common to both power measurements, to measure voltage by TV. 0.2% precision of the configured full scale.
  • Maximum effective current measured by CT: 60 Arms / maximum cable diameter: 8.5 mm
  • 1 digital relay output, 1 exchange contact, 230Vac 5A max
  • 2 free digital contacts suitable for photosensors to read the meter
  • 2 digital inputs suitable for connection to a free contact. These 2 inputs could also be used, with a different configuration, as analog inputs for measuring the temperature by NTC, 10 bit resolution.
  • All the connections are secured by screw clamps
  • 1 USB input for updating the instrument
  • Interface to the local network and internet by LAN, WIFI or GPRS/3G
  • 868 MHz radio interface for communicating with the CLEVER VIEW user interface
  • Discreet design plastic case for mounting on a 4-module DIN bar


Clever View

Componenti 2
  • +5 V DC power feed
  • Maximum absorbed power 2W by USB connector
  • Backup power by single-cell 400 mAh lithium battery, rechargeable in 5 hours
  • 3.5” TFT display rear lit by led
  • Resistive Touchscreen
  • 868 MHz radio interface for connection to the CLEVER
  • Polycarbonate case measuring 150 x 110 mm, 28 mm thick, with table stand or wall fitting
  • Glossy black colour


Clever Power Sensor

Componenti 3
  • Maximum current, effective (and peak) current CT 60 Arms
  • Calibrated at 0.15% with phase correction on CLEVER
  • DC current tolerated without affecting the readings
  • Cable length 1,200 mm
  • Maximum cable diameter 8.5 mm
  • Size 37 mm x 75 mm, d 18 mm


Clever Pick-up

Clever Pick-up
Device equipped with photo-diode for reading the production and/or grid meter.

Available in the wired or 868 MHz radio version


Clever Antenna WiFi

Clever Antenna WiFi
  • For use when there is a poor signal from the access point
  • Adhesive film attachment on the outside of the electric control panel
  • Cable length 400 mm
  • Size 115 x 20 mm, 5 mm thick
  • Gain 6 dBi


Clever Antenna GPRS

Clever Antenna GPRS
  • For use when there is poor coverage by the GPRS signal
  • Antenna base with magnet for attaching to a metal base, or adhesive film for attaching to the outside of the electric control panel
  • Cable length 3,000 mm
  • Size base diameter 30 mm, h = 300 mm
  • Gain 3 dB


Access Point WiFi

Access Point WiFi
  • Preconfigured for interface with CLEVER BOX WiFi
  • Wireless conformity IEEE 802.11b IEEE 802.11g IEEE 802.11n
  • LAN conformity IEEE 802.3IEEE 802.3uIEEE 802.1xIEEE 802.1q
  • Wireless encryption WEP Encryption-64/128 bit WPA Personal (WPA-PSK using TKIP or AES) WPA Enterprise (WPA-EAP using TKIP) 802.1x Authenticator 802.1x Supplicant-MD5/TTLS (CB & CR mode) Hide SSID in beacons
  • Support ip IPv4
  • Optional antenna connector SMA-Reverse
  • Maximum height 26 mm
  • Maximum width 123 mm
  • Maximum depth 105 mm


Router LAN

Router LAN
  • 4 LAN ports
  • LAN speed 10/100 Mbps IEEE 802.3 IEEE 802.3u IEEE 802.3x IEEE 802.1x
  • Wan Fast Ethernet connection
  • Backup wan Dynamic IP Static IP PPPoE 802.1X + Dynamic IP 802.1X + Static IP L2TP PPTP
  • IPv4 support
  • Integrated firewall YES
  • Vpn support YES
  • CE, RoHS, SFT, EMC conformity declarations
  • Maximum width 165 mm
  • Maximum depth 108 mm
  • Maximum height 28 mm